Features
Specifications
| SPECIFICATIONS | ||||||||
| OUTPUT | ||||||||
| Model | SP-200-5 | SP-200-7.5 | SP-200-12 | SP-200-13.5 | SP-200-15 | SP-200-24 | SP-200-27 | SP-200-48 |
| DC Voltage | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V |
| Rated Current | 40A | 26.7A | 16.7A | 14.9A | 13.4A | 8.4A | 7.5A | 4.2A |
| Current Range | 0-40A | 0-26.7A | 0-16.7A | 0-14.9A | 0-13.4A | 0-8.4A | 0-7.5A | 0-4.2A |
| Rated Power | 200W | 200.2W | 200.4W | 201.1W | 201W | 201.6W | 202.5W | 201.6W |
| Ripple & Noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | 250mVp-p |
| DC Adjustment Range | -5%,+10% | -5%,+10% | -5%,+10% | -5%,+10% | -5%,+10% | -5%,+10% | -5%,+10% | -5%,+10% |
| Voltage Tolerance | ±2% | ±2% | ±2% | ±2% | ±2% | ±1% | ±1% | ±1.0% |
| Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load Regulation | ±1% | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Setup, Rise, Hold Up Time | 600ms,40ms,20ms at full load | |||||||
| INPUT | ||||||||
| Voltage Range | 85~264 VAC 47-63Hz;120~370VDC | |||||||
| AC Current | 3.5A/115 VAC 1.7A/230VAC | |||||||
| Power Factor | PF>0.93/230VAC,PF>0.97/115VAC at full load | |||||||
| Efficiency | 71% | 76% | 79% | 80% | 81% | 83% | 83% | 84% |
| Inrush Current | Cold start 50A/230VAC | |||||||
| Leakage Current | <2mA/240VAC | |||||||
| PROTECTION | ||||||||
| Over Load | 105%-150% rated output power | |||||||
| Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||||||
| Over Voltage | 110%~135% | |||||||
| Protection type: Shut down o/p voltage, re-power on to recover | ||||||||
| Over Temp. | 80±5℃ (TWS1:detect on heatsink of power transistor) | |||||||
| Protection type: shutdown o/p voltage, recovers automatically after temperature goes down | ||||||||
| Function | ||||||||
| Remote Control (option) | CN3:4~10VDC POWER OFF, <0~0.8VDC POWER ON | |||||||
| ENVIRONMENT | ||||||||
| Working Temp. Humidity | -10℃~+60℃; 20%~90% RH non-condensing | |||||||
| Storage Temp. Humidity | -20℃~+85℃; 10%~95% RH | |||||||
| Temp. Coefficient | ±0.05%/℃(0~50℃) | |||||||
| Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |||||||
| SAFETY | ||||||||
| Withstand Voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG: 0.5KVAC | |||||||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/25℃/70% RH | |||||||
| STANDARD | ||||||||
| Safety Standard | Design refer to UL60950-1,TUV EN60950-1, CCC | |||||||
| EMC Standard | Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024, light industry level, criteria A | |||||||
| OTHERS | ||||||||
| Dimension | 199*99*50mm (L*W*H) | |||||||
| Weight | 0.85Kg/pc; 20pcs/17.9kg/1.28CUFT | |||||||
| NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | |||||||
| 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. | ||||||||
| 3. Tolerance: includes set up tolerance, line regulation and load regulation. | ||||||||
| 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | ||||||||